Dry cleaner TORNADOR M-2030
  • Product group:   515
  • Item number:   M-2030

 

  • Auto Chemistry: Interior Cleaner M-760

Dry cleaner TORNADOR M-2030

A professional device of the second generation, which allows, with a minimum consumption of detergent, to clean even heavily contaminated surfaces and parts of the car as quickly and efficiently as possible.

 

It is recommended to use the universal interior cleaner M-760

It is used to clean the passenger compartment, body ceiling, dashboard, ventilation holes, mats, discs, engine and other parts of the machine, regardless of the sensitivity, accessibility and degree of contamination of the treated surface.
The Tornador M-2030 integrates a pressure control valve that automatically reduces or increases the volume of the exhaust composition or air depending on the distance of the nozzle from the treated surface. After treatment, the surface remains practically dry.

Design of the spout
Metal nozzle and three bearings
Free rotation speed
5000 rpm
Air flow
130 L/min
Composition consumption
6 L/h
Weight
0.8 kg
Фото

The device has two positions:

  1. Supply of composition under air pressure – detergent solution under pressure is supplied to contaminated surface.
  2. Air supply, which allows you to «knock out» dirt from the treated surface – the effect of a «tornado» created by a spinning spout inside the neck of the device. Dirt removed from the surface settles in the neck, which is cleaned by simple immersion in water and air supply.

 

Technical specifications:

  • Free rotation speed: 5000 rpm.
  • Air consumption: 130 L/min.
  • Composition consumption: 6 L/h.
  • Air inlet: 1/4”.
  • Optimum air pressure: 6.2 bar.
  • Weight: 0.8 kg.

Instructions and recommendations:

  1. Use only recommended cleaning agents – do not use detergents containing chlorine.
  2. Avoid using excessively high air pressure – pressures over 9 bar significantly accelerate the wear of the neck and inner tubes.
  3. Before starting work, the surface to be treated must be thoroughly vacuumed.
  4. Do not leave the unit connected to the air line – use the convenient quick release coupling to disconnect when work is finished or a break is required.
  5. In order to avoid uncontrolled spillage of the working solution during a break in the unit’s operation, the chemistry supply valve should be turned to the horizontal position.
  6. During operation it is necessary to keep the inner surface of the neck clean. In case of contamination, lower the neck 5-7 cm into a container with water and remove the dirt by two-three short presses on the trigger.
  7. After completion of all work, unscrew the neck and thoroughly rinse all working surfaces and elements with clean water.
  8. The installation of an oil trap in the air line is recommended.

Technical specifications

Design featuresMetal nozzle and three bearings
Free rotation speed5000 rpm
Air flow rate130 L/min
Composition consumption6 L/h
Air inlet1/4”
Optimal air pressure6.2 bar
Weight0.8 kg

Equipment requirements

Air pressure8-12 kg
Receiver volumefrom 150 L